1.查看IP地址命令 ................................................................................................................. 2 2.查看firmware版本 ............................................................................................................. 2 3.查看交换机状态 ................................................................................................................... 2 4.查看交换机license-id ...................................................................................................... 3 5.配置ZONE .............................................................................................................................. 3 6.查看zone配置文件 ............................................................................................................. 4 7.查看ZONE .............................................................................................................................. 5 8.查看系统日志信息 ............................................................................................................... 6 9.关机 ....................................................................................................................................... 6 10.设置博科Brocade交换机IP地址 ................................................................................... 6 11.博科brocade交换机查看OS版本信息 ........................................................................... 6 12.博科brocade交换机添加license授权信息 ................................................................. 7 13.查看博科brocade交换机license授权信息 ................................................................. 7 14.博科Brocade Slikworm 300交换机license ................................................................ 7 15.博科Brocade交换机修改密码命令 ................................................................................. 7 16.博科 brocade SAN交换机密码重置 ................................................................................ 7 17.登陆后是用passwddefault命令恢复出厂密码 ............................................................. 9 18.交换机升级 ......................................................................................................................... 9 19.帮助信息 ........................................................................................................................... 13

1.查看IP地址命令

swd77:admin>ipaddrshow SWITCH

Ethernet IP Address: 10.77.77.77 Ethernet Subnetmask: 255.255.255.0 Fibre Channel IP Address: none Fibre Channel Subnetmask: none Gateway IP Address: none DHCP: Off swd77:admin>

2.查看firmware版本 swd211:admin>

swd211:admin>firmwareshow

Appl Primary/Secondary Versions

------------------------------------------ FOS v6.2.1 v6.2.1

3.查看交换机状态

swd211:admin>switchoshow

rbash: switchoshow: command not found swd211:admin> switchshow switchName: swd211 switchType: 34.0

switchState: Online switchMode: Native switchRole: Principal switchDomain: 1

switchId: fffc01

switchWwn: 10:00:00:05:1e:02:a2:10 zoning: ON (FC01) switchBeacon: OFF

Area Port Media Speed State Proto =====================================

0 0 id N2 Online F-Port 50:08:05:f3:00:1b:4e:91 1 1 id N4 Online F-Port 10:00:00:00:c9:53:b2:8d 2 2 id N4 Online F-Port 10:00:00:00:c9:53:b3:c1 3 3 id N4 Online F-Port 10:00:00:00:c9:53:b3:c2 4 4 id N4 Online F-Port 50:06:0b:00:00:66:00:c4 5 5 id N4 Online F-Port 50:06:0b:00:00:66:01:1e 6 6 id N2 Online F-Port 50:05:08:b3:00:93:b2:81

7 7 -- N4 No_Module

8 8 id N4 Online F-Port 50:01:43:80:04:c7:87:d8 9 9 id N4 Online F-Port 50:01:43:80:04:c7:87:dc 10 10 id N4 Online F-Port 50:01:43:80:06:31:cf:7c 11 11 -- N4 No_Module 12 12 -- N4 No_Module 13 13 -- N4 No_Module 14 14 -- N4 No_Module 15 15 -- N4 No_Module swd211:admin>

4.查看交换机license-id swd211:admin>

swd211:admin>licenseidshow 10:00:00:05:1e:02:a2:10 swd211:admin>

5.配置ZONE 案例:

1) Create Aliases

>alicreate “Eng_Host”,“1,0”

>alicreate “Eng_Stor”,“1,4; 1,5” >alicreate “Mkt_Host”,“Mktwwn”

>alicreate “Mkt_Stor”,“s3wwn; s4wwn; s5wwn” 2) Create Zones

>zonecreate “Zone_Eng”,“Eng_Host; Eng_Stor” >zonecreate “Zone_Mkt”,“Mkt_Host; Mkt_Stor” 3) Create Configuration

>cfgcreate “Cfg_EngMkt”,“Zone_Eng; Zone_Mkt”

sw4100:admin> cfgshow Defined configuration: cfg: Cfg_EngMkt Zone_Eng; Zone_Mkt

zone: Zone_Eng Eng_Host; Eng_Stor zone: Zone_Mkt Mkt_Host; Mkt_Stor alias: Eng_Stor 1,4; 1,5 alias: Eng_Host 1,0

alias: Mkt_Stor 21:00:00:20:37:87:49:29; 21:00:00:20:37:87:e5:20; 21:00:00:20:37:87:20:c5

alias: Mkt_Host 21:00:00:20:37:87:23:e2 Effective configuration:

no configuration in effect

4) Enable Configuration >cfgenable “Cfg_EngMkt”

sw4100:admin> cfgshow Defined configuration: cfg: Cfg_EngMkt one_Eng; Zone_Mkt

zone: Zone_Eng Eng_Host; Eng_Stor zone: Zone_Mkt Mkt_Host; Mkt_Stor alias: Eng_Stor 1,4; 1,5 alias: Eng_Host 1,0

alias: Mkt_Stor 21:00:00:20:37:87:49:29; 21:00:00:20:37:87:e5:20; 21:00:00:20:37:87:20:c5

alias: Mkt_Host 21:00:00:20:37:87:23:e2 Effective configuration: cfg: Cfg_EngMkt

zone: Zone_Eng 1,0; 1,4; 1,5

zone: Zone_Mkt 21:00:00:20:37:87:23:e2; 21:00:00:20:37:87:e5:20; 21:00:00:20:37:87:49:29; 21:00:00:20:37:87:20:c5

6.查看zone配置文件 swd211:admin>

swd211:admin>cfgshow Defined configuration:

cfg: FC01 OADB_ML6030; SPC_MSA1000; SFDB_EVA4400; SFDB04_MSA1500; SFEVA4400_SMA zone: OADB_ML6030

1,7; 1,14; 1,15 zone: SFDB04_MSA1500 1,10; 1,6 zone: SFDB_EVA4400

1,3; 1,4; 1,5; 1,7; 1,8; 1,9 zone: SFEVA4400_SMA

1,8; 1,9; 1,11 zone: SPC_MSA1000

1,0; 1,1; 1,2; 1,7

Effective configuration: cfg: FC01

zone: OADB_ML6030 1,7 1,14 1,15 zone: SFDB04_MSA1500

1,10 1,6 zone: SFDB_EVA4400 1,3 1,4 1,5 1,7 1,8 1,9 zone: SFEVA4400_SMA 1,8 1,9 1,11 zone: SPC_MSA1000 1,0 1,1 1,2 1,7

swd211:admin> swd211:admin>

7.查看ZONE

swd211:admin>zoneshow Defined configuration:

cfg: FC01 OADB_ML6030; SPC_MSA1000; SFDB_EVA4400; SFDB04_MSA1500; SFEVA4400_SMA zone: OADB_ML6030

1,7; 1,14; 1,15 zone: SFDB04_MSA1500 1,10; 1,6 zone: SFDB_EVA4400

1,3; 1,4; 1,5; 1,7; 1,8; 1,9 zone: SFEVA4400_SMA

1,8; 1,9; 1,11 zone: SPC_MSA1000

1,0; 1,1; 1,2; 1,7

Effective configuration: cfg: FC01

zone: OADB_ML6030 1,7 1,14 1,15

zone: SFDB04_MSA1500 1,10 1,6 zone: SFDB_EVA4400 1,3 1,4 1,5 1,7 1,8 1,9 zone: SFEVA4400_SMA 1,8 1,9 1,11 zone: SPC_MSA1000 1,0 1,1 1,2 1,7 swd211:admin>

8.查看系统日志信息

swd211:admin>supportshow 日志比较多,建议log出来查看.

9.关机

swd211:admin>sysshutdown

10.设置博科Brocade交换机IP地址

博科交换机的默认IP地址是10.77.77.77,在命令行模式下可以通过ipaddrset命令对交换机的IP地址进行设置和修改 swd77:admin>ipaddrset

Ethernet IP Address [10.77.77.77]: #输入交换机需要设置的IP地址 Ethernet Subnetmask [255.255.255.0]: #输入掩码 Fibre Channel IP Address [none]: Fibre Channel Subnetmask [none]:

Gateway IP Address [none]: # 输入网关 DHCP [Off]: #是否开启DHCP swd77:admin>

11.博科brocade交换机查看OS版本信息 swd77:admin>version

Kernel: 2.6.14.2 //linux内核版本 Fabric OS: v6.1.0a // 交换机OS版本

Made on: Thu Apr 17 21:45:31 2008 // 生产日期 Flash: Tue Jan 13 23:33:44 2009 BootProm: 4.6.6 swd77:admin>

12.博科brocade交换机添加license授权信息

swd77:admin>licenseadd XXXXXXXX(博科的激活号)

13.查看博科brocade交换机license授权信息

在命令行模式下使用licenseshow命令可以查看博科交换机的授权情况,使用licenseadd命令可以添加授权。

博科Brocade Slikworm 210E交换机授权情况 swd77:admin> licenseshow RzcQSXXXCS0RTc: Unknown1 license S9zXXXCSzRTScl: Unknown2 license b9QQGGHJHARRdF: Fabric license swd77:admin>

其中两个Unknown1 和Unknown2这两个授权应该是两个4端口的授权。Fabric license是级联license授权,是我后来添加的,默认的210E交换机是没有的。

14.博科Brocade Slikworm 300交换机license swd77:admin>licenseshow

XSCJBCmH3SARFa7BXrVVBGGFFRRXBArGR:

Fabric license //级联License

Enhanced Group Management license //增强组管理授权 8 Gig FC license //8Gb的授权 swd77:admin>

15.博科Brocade交换机修改密码命令

Brocade交换机在命令行模式下可以通过passwd命令来修改用户密码: 以brocade 300为例:

swd77:admin>passwd #使用passwd命令修改当前用户密码 Changing password for admin

Enter old password: #输入目前使用的密码 Enter new password: #输入新密码 Re-type new password: #确认新密码

passwd: all authentication tokens updated successfully Saving password to stable storage.

Password saved to stable storage successfully. swd77:admin>

16.博科 brocade SAN交换机密码重置

博科300的默认用户名是admin,默认密码是password。由于这台机器用户做过设置,密码改过了需要重设一下。博科交换机是没有reset按钮的,必须通过console线连接通过命令重置。

博科300的os是用的linux 2.6的核心,最高权限的管理帐号是root。重置交换机密码就是用这个帐号。 swd77 login: root Password: fibranne

使用该帐号登陆后会出现下面的信息:

Disclaimer for Root and Factory Accounts Usage!

This Fibre Channel switch is equipped with Root and Factory accounts that are intended for diagnostics and debugging purposes solely by the Equipment vendor's trained engineers. Improper use of the

functionality made available through the Root or Factory account could cause significant harm and disruption to the operation of the SAN fabric. Your use of the functionality made available through the Root or Factory account is at your sole risk and you assume all liability resulting from such use. The Equipment vendor shall have no liability for any losses or damages arising from or relating to the use of the Root or Factory account (and the functionality enabled thereby) by anyone other than the Equipment vendor's authorized engineers.

Proceeding with the usage of this switch as the Root or Factory user explicitly indicates your agreement to the terms of this disclaimer. Please change passwords for switch default accounts now. Use Control-C to exit or press 'Enter' key to proceed.

这里用Control-C结束就行了,如果回车会让分别设置各个帐号的密码,出现如下信息: Warning: Access to the Root and Factory accounts may be required for proper support of the switch. Please ensure the Root and Factory passwords are documented in a secure location. Recovery of a lost Root or Factory password will result in fabric downtime. for user - root

Changing password for root Enter new password: Password unchanged.

passwd: Authentication token manipulation error

Please change passwords for switch default accounts now. for user - factory

Changing password for factory Enter new password: Password unchanged.

passwd: Authentication token manipulation error

Please change passwords for switch default accounts now. for user - admin

Changing password for admin Enter new password:

Password unchanged.

passwd: Authentication token manipulation error

Please change passwords for switch default accounts now. for user - user

Changing password for user Enter new password: Password unchanged.

passwd: Authentication token manipulation error

17.登陆后是用passwddefault命令恢复出厂密码 swd77:root>passwddefault

Password policies are already set to default.

All account passwords have been successfully set to factory default. swd77:root>

18.交换机升级

将Brocade 200E交换机现有微码版本v5.0.1b 升级至v6.2.1,具体操作步骤如下:

1、 资源准备:网线一根,BROCADE 200E firmware version ,控制台(PC或笔记本),要安装Java JRE 1.5版本以上

2、 设备连接:用网线将控制台(PC 或笔记本)的网卡连接到交换机的管理口上。 3、 控制台环境设置:将控制台的网卡IP地址设备为10.77.77.1,子网掩码为

255.255.255.0。然后在控制台的安装FTP服务或软件,FTP的根目录设置为版本软件所在的目录,并设置一个用户lab,密码为lab123。

确认控制台与交换机(brocade)的网络连接正常。执行以下命令: Ping 10.77.77.77 (默认管理口地址) 4、 登陆交换机:输入telnet 10.77.77.77 ,用户名为:admin,密码为:password,登录到交换机。登陆进入后,会提示更改admin帐户的密码,如需更改直接回车,不更改则按ctrl + c 。

5、 登录后输入firmwareshow,回车,可以查看现有的微码版本,如果不是v6.2.1,则需要升级到v6.2.1。 Concept

1). Every Brocade switch has 2 partitions (one is master, the other is slave). 2). Switch can be upgrade online

3). Slave upgrade first, after the slave partition upgraded, slave partition become master, master become slave, then firmware copy from master to slave Version Information:

Port Speed Product Firmware Version Upgrade info 2GB 3900 4.x or 5.x v5.2.0a or v5.3.0c 2GB 12000 4.x or 5.x v5.2.0a or v5.3.0c 4GB 42000 4.x or 5.x v5.2.0a or v5.3.0c

NOTICE:

1> when current Version is 4.4.2 or later, Please Online Upgrade. 2> Before Upgrade firmware, please backup current configuration. 3> Copy new version firmware packages to ftp server directory.

Upgrade Firmware process (Step by Step)

This is demo switch from Brocade Shanghai office. Don't change IP address please. If you meeproblem

swd77 login: admin Password:

swd77:admin> version Kernel: 2.4.19

Fabric OS: v4.4.0d // Please check current version Made on: Wed May 18 21:08:14 2007 Flash: Mon Jun 6 06:35:26 2007 BootProm: 4.5.0

swd77:admin>configupload //backup the switch configuration Protocol (scp or ftp) [ftp]: ftp

Server Name or IP Address [host]: 202.134.79.36 //ftp server ip-address User Name [user]: lab//ftp server user name File Name [config.txt]: config.txt // specify configuration file name Password: //ftp server user password Upload complete

swd77:admin>firmwaredownload//download new version firmware

You can run firmwareDownloadStatus to get the status of this command. This command will cause the switch to reset and will require that existing telnet, secure telnet or SSH sessions be restarted.

Do you want to continue [Y]: y

Server Name or IP Address: 10.77.77.1//ftp server ip-address

User Name: admin //ftp server user name

File Name: /v5.1.0/v5.1.0/release.plist /v5.2.0/v5.2.0/release.plist /v5.3.0/v5.3.0/release.plist /v6.0.0/v6.0.0/release.plist /v6.1.0/v6.1.0/release.plist /v6.2.1/v6.2.1/release.plist

Password: //ftp server user password

注意: 升级需要30分钟的格式化,需要10分钟的备分区同步版本,总共花销时间需:40分钟

[0]: Sun Feb 19 05:59:40 2012 Firmware is being downloaded to the switch. This step may take up to 30 minutes. [1]: Sun Feb 19 06:04:35 2012 Firmware has been downloaded to the secondary partition of the switch.

[2]: Sun Feb 19 06:06:15 2012 The firmware commit operation has started. This may take up to 10 minutes.

firmwareshow检查版本是否主分区与备分区同步

Firmwaredownload has started. Start to install packages......

dir ##################################################

ldconfig ################################################## glibc##################################################

bash ################################################## readline ################################################## terminfo ################################################## termcap ################################################## setup ################################################## swbd12-setup ################################################## which ################################################## findutils ################################################## bzip ################################################## zlib ################################################## chkconfig ################################################## fileutils ################################################## sed ################################################## textutils ################################################## procps ################################################## psmisc ################################################## modutils ################################################## sin ################################################## rcinit ################################################## misc ################################################## pam ################################################## util-linux ##################################################

sh-utils ################################################## popt ################################################## grep ################################################## rpm ################################################## sysvinit ################################################## man ################################################## less ################################################## gzip ################################################## tar ################################################## rsync ################################################## cpio ################################################## dev ################################################## swbd23-bootenv ################################################## wdtd ################################################## wget ################################################## fwdl ################################################## swbd23-prom ################################################## Please avoid powering off the system during prom update.

kernel ################################################## swbd21-drivers ################################################## pcmcia-cs ################################################## sysklogd ################################################## Write kernel image into flash. .............................. Verification SUCCEEDED

Removing unneeded files, please wait ... Finished removing unneeded files.

All packages have been downloaded successfully. Firmwaredownload has completed successfully.

HA Rebooting ... // waiting for upgrade another controller

Fabric OS (swd77)

Firmwaredownload command has completed successfully.

swd77:admin>firmwareshow//check firmware version for all controller Primary partition: v4.4.2 Secondary Partition: v4.4.2 swd77:admin>

-End-

19.帮助信息

swd211:admin>help

aaaconfig Configure RADIUS for AAA services

ad Specifies all administration domain (AD)-level operations

ag Configure the Access Gateway feature

agshow Displays the Access Gateway information registered with the fabric

agtcfgdefault Reset SNMP agent to factory default aliadd Add a member to a zone alias alicreate Create a zone alias alidelete Delete a zone alias

aliremove Remove a member from a zone alias alishow Print zone alias information

aptpolicy Get and set Advanced Performance Tuning policy auditcfg Modifies and displays audit log filter configuration.

auditdump Display audit log

authutil Get and set authentication configuration

backplanetest Backplane connection test for multi-blade systems. backport Test for back-end ASIC pair to ASIC pair links. bannerset Set security banner bannershow Display security banner

bcastshow Display broadcast routing information bladedisable Disables all user ports on a blade. bladeenable Enables all User Ports on a blade.

bpportloopbacktest Functional test of port via blade processor path. bpturboramtest MBIST test for AP blade BP ASICs

burninerrclear Clear errors that are stored in the non-volatile storage

burninerrshow Display errors that are stored in the non-volatile storage

burninstatus Display the diagnostics burnin status.

camtest Verify QuickLoop's Content Addressable Memory (CAM).SID translation

centralmemorytest Test ASIC central memory operation.

cfgactvshow Display Effective zone configuration information cfgadd Add a member to a configuration cfgclear Clear all zone configurations cfgcreate Create a zone configuration cfgdelete Delete a zone configuration cfgdisable Disable a zone configuration cfgenable Enable a zone configuration

cfgmcdtmode Configure legacy MCDT zoning behavior

cfgremove Remove a member from a configuration cfgsave Save zone configurations in flash

cfgsaveactivetodefined Moves the effective configuration to the defined configuration

cfgshow Print zone configuration information cfgsize Print size details of zone database cfgtransabort Abort zone configuration transaction

cfgtransshow Print zone configurations in transaction buffer chassisbeacon Set chassis beacon on or off

chassisconfig Display or set the chassis configuration chassisdisable Disable all ports in chassis chassisenable Enable all ports in chassis

chassisname Display or set the chassis's Name

chassisshow Display all Field Replaceable Units (FRU) chipregshow Displays the port registers for a given chip number.

clihistory Displays a log of most recently executed CLI commands

cmemretentiontest Data retention test of the central memory SRAMs. cmitest Verify CMI bus between ASICs. configdefault Reset config to factory default configdownload Load switch config from a server configlist List the stored config files configremove Remove a stored config file configshow Print switch config parameters configupload Save switch config to a server

configure Set logical switch config parameters configurechassis Set chassis config parameters

cryptocfg Configure encryption node functions

datatypeshow Display available diagnostic data types. date Print/set the system date and time

dbgshow Display debug levels of various modules defzone Activates or deactivates a default zone configuration.

diagclearerror Clears diagnostics failure status.

diagcommandshow Display diagnostic command descriptions. diagdisablepost Disable diagnostic POST. diagenablepost Enable diagnostic POST.

diaghelp Display diagnostic command descriptions. diagloopid Select the diagnostics loop ID.

diagmodeshow Displays diagnostic mode configuration.

diagpost Displays the contents of port registers and memories.

diagretry Sets diagnostic retry mode

diagsetcycle Set diagnostic script parameters. diagsetesdmode Set or display ESD mode.

diagsetshowtime Set or display diagnostic show-time mode. diagshow Display diagnostic status.

diagshowtime Set or display diagnostic show-time mode. diagstatus Display currently running diagnostic tests. distribute Distributes data to switches in a fabric.

dlsreset Turn off the dynamic load sharing (DLS) option dlsset Turn on the dynamic load sharing (DLS) option dlsshow Display the state of the dynamic load sharing option

dnsconfig Configure DNS service

enclosureshow Display the switch enclosure attributes errclear Clear error log

errdelimiterset Sets the error log start and end delimiter for messages sent to the console and syslog

errdump Print error log (no page breaks)

errfilterset Sets a filter for an error log destination errmoduleshow Displays all the defined modules in the system errshow Print error log

fabportshow Display contents of a particular port's data fabretryshow Display retry count of various fabric commands fabriclog Displays or manipulates the fabric log fabricprincipal Configure Principal Switch Selection mode fabricshow Print fabric membership info

fabstateclear Clears the fabric state information fabstateresize Changes the number of state entries fabstateshow Displays the fabric state information

fabstatsshow Displays the fabric statistics information fabswitchshow Display fabric switch state information fandisable Disables a fan unit. fanenable Enables a fan unit. fanshow Print fan status

fastboot Reboot this switch and bypass POST fastwritecfg Configure FC fastwrite feature

fcipchiptest Functional Test of Components in FCIP Complex. fciphelp Print FCIP help info

fcippathtest Data Path Test of the FCIP complex. fcping Sends a FC ELS ECHO request to a port fcplogclear Clear the FCP log

fcplogdisable Disable logging of FCP events fcplogenable Enable logging of FCP events

fcplogshow Display FCP probing log information fcpprobeshow Display FCP probing information

fcprlsshow Display FCP RLS (read link state) information fcrbcastconfig Configure interfabric broadcast frame forwarding fcrchiptest Functional Test of FCR FPGA.

fcrconfigure Sets FC Router configuration parameters. fcrfabricshow Displays FC Routers on a backbone fabric. fcrlsan Configure LSAN policies

fcrlsancount Display maximum LSAN zone limit.

fcrlsanmatrix Manage LSAN fabric matrix configuration.

fcrpathtest Data Path Test on Connection between FCR FPGA and Central ASIC.

fcrphydevshow Displays FC Router physical device information. fcrproxyconfig Displays or configures proxy devices presented by an FC Router.

fcrproxydevshow Displays FC Router proxy device information. fcrresourceshow Displays FC Router physical resource usage. fcrrouterportcost Modify FC Router port cost configuration. fcrrouteshow Displays FC Router route information.

fcrxlateconfig Displays or persistently configures a translate (xlate) domain's domain ID for both EX_Port-attached fabric and backbone fabric.

fddcfg fddcfg manages the fabric data distribution configuration parameters.

fdmicacheshow Display abbreviated remote FDMI device information according to remote domain ID

fdmishow Display detailed FDMI device information

ficonclear Clears contents of the specified FICON management database

ficoncupset Sets FICON-CUP parameters for a switch ficoncupshow Displays FICON-CUP parameters for a switch ficonhelp Displays FICON commands

ficonshow Displays contents of the specified FICON management database

filtertest Run frame filter test for bloom ASICs. fipscfg Configure FIPS mode operation firmwarecommit Commit firmware to stable storage firmwaredownload Download firmware into switch

firmwaredownloadstatus Display the progress and status of firmwareDownload firmwarekeyshow Manage the keys used to check firmware signatures firmwarekeyupdate Manage the keys used to check firmware signatures firmwarerestore Restore the old firmware in the switch firmwareshow Display firmware versions in the switch fosconfig Enable/disable FabOS services

fosexec Invoke command in alternate VF context

fporttest Functional test of F->N N->F point to point path.

framerpathtest Tests data path between ASICs frureplace Replace a Field Replacable Unit fspfshow Print FSPF global information

fwalarmsfilterset Configure alarms filtering for Fabric Watch fwalarmsfiltershow Show alarms filtering for Fabric Watch fwclassinit Initialize all Fabric Watch classes fwconfigreload Reload Fabric Watch configuration fwconfigure Configure Fabric Watch

fwfrucfg Configure FRU state and notification fwhelp Print Fabric Watch help info

fwmailcfg Configure Fabric Watch Email Alert

fwportdetailshow Create a report with detailed port information fwsamshow Show availability monitor information fwset Set port persistence time

fwsettocustom Set boundary & alarm level to custom fwsettodefault Set boundary & alarm level to default

fwshow Show thresholds monitored and port persistence time grep Linux grep command h Print shell history

hadisable Disables the High Availability feature in the switch.

hadump Displays information about the status of the High Availability feature in the switch.

haenable Enables the High Availability feature in the switch hafailover Forces the failover mechanism so that the Standby Control Processor (CP)becomes the Active CP. hashow Displays control processor (CP) status hasyncstart Enables HA state synchronization.

hasyncstop Disables the HA state synchronization. help Print this list

historylastshow Displays last history record

historymode Display or set the mode of the history log historyshow Displays entire history log

httpcfgshow Used to show the version of the Java plug-in used by the Webtools

i Display process summary iclcfg Configure ICL state

ifmodeset Set the link operating mode for a network interface ifmodeshow Display the link operating mode for a network interface

interfaceshow Display the FSPF (TM) interface information interopmode Displays/enables/disables Brocade switch interoperability with switches from other manufacturers

ioddelayreset Configure in-order-delivery (IOD) delay parameter ioddelayshow Configure in-order-delivery (IOD) delay parameter iodreset Turn off the in-order delivery (IOD) option iodset Manage the in-order delivery (IOD) option

iodshow Display the state of the in-order delivery option ipaddrset Set ethernet and FC IP addresses ipaddrshow Print ethernet and FC IP addresses ipfilter Manage/display IP filters ipsecconfig Configure IPSec feature iscsihelp Print iSCSI help info

islshow Display the current connections and status killtelnet Terminate telnet/serial login sessions interactively

ldapcfg Configure LDAP role mapping ledtest Cycle system LEDs.

lfcfg Configure logical fabrics

lfexec Invoke command in alternate VF context licenseadd Adds license keys to switch licensehelp Print license help info

licenseidshow Displays the system license ID

licenseport Configure per-port POD license assignments licenseremove Removes a license key from this system licenseshow Displays current license keys

linkcost Set or print the FSPF cost of a link login Login as a new user

logout Logout from remote session

loopporttest Functional test of L-port M->M path on a loop. lscfg Configure logical switches

lsdbshow Displays the FSPF link state database memshow Display memory usage in the system. minispropshow Displays ASIC pair properties. more Linux more command

mscapabilityshow Display Management Server Capability. msconfigure Configure Management Server

msplatshow Display the Management Server Platform Database msplatshowdbcb Display the Management Server Database Control Block

msplcleardb Clear the Management Server Platform Database fabric-wide

msplmgmtactivate Activate the Management Server Platform Database fabric-wide

msplmgmtdeactivate Deactivate the Management Server Platform Database fabric-wide

mstddisable Disables the Management Server Topology Discovery

Management Service

mstdenable Enables the Management Server Topology Discovery Management Service

mstdreadconfig Display status of Management Server Topology Discovery Service

myid Display the current login session details nbrstateshow Display FSPF (TM) neighbors' states nbrstatsclear Reset the FSPF (TM) interface counters netstat Display network connections and statistics

nodefind Display all the devices' PID matching the given world wide name

nsaliasshow Display local Name Server information with Aliases nsallshow Print global Name Server information

nscamshow Print local Name Server Cache information

nsshow Print local Name Server information information nszonemember Display the information of all the online devices which are zoned with the given device.

opensource Display information on open source software utilized in FabOS

passwd Set usernames and passwords

passwdcfg passwdcfg manages the password policies.

pathinfo Display routing information between two ports pdshow Show information from Panic Dump file perfaddeemonitor Add end-to-end monitor

perfaddipmonitor Add monitor for IP trafic frame count perfaddreadmonitor Add filter-based monitor - SCSI Read perfaddrwmonitor Add monitor - SCSI Read and Write perfaddscsimonitor Add monitor for SCSI frame count perfaddusermonitor Add filter-based monitor

perfaddwritemonitor Add filter-based monitor - SCSI Write perfcfgclear Clear Performance settings from FLASH

perfcfgrestore Restore Performance configuration from FLASH perfcfgsave Save Performance configuration to FLASH

perfclearalpacrc Clears the CRC error count associated with a port and Arbitrated Loop Physical Address (AL_PA).

perfcleareemonitor Clears statistics counters of one or more end-to-end performance monitors.

perfclearfiltermonitor Clears counters of one or more filter-based performance monitors.

perfdeleemonitor Delete end-to-end monitor perfdelfiltermonitor Delete filter-based monitor

perfhelp Print Performance Monitoring help info perfmonitorclear Clear end-to-end/filter-based/ISL monitors perfmonitorshow Show end-to-end/filter-based/ISL monitors

perfsetporteemask Set overall mask for end-to-end monitors perfshowalpacrc Get ALPA CRC count by port and ALPA perfshoweemonitor Show user-defined end-to-end monitors perfshowfiltermonitor Show filter-based monitors

perfshowporteemask Show the current end-to-end mask perfttmon Configure bandwidth usage monitor

ping Display the link operating mode for a network interface

ping6 Display the link operating mode for a network interface

pkicreate Creates public key infrastructure (PKI) objects pkiremove Removes existing public key infrastructure (PKI) objects

pkishow Displays existing public key infrastructure (PKI) objects

policy Configure IPSec encryption and authentication algorithms

portaddress Configure low 16 bits of Fibre Channel Porrt ID portalpashow Show the ALPAs of a port

portbuffershow Print the buffer allocations for the ports of a quad

portcamshow Display filter utilization

portcfg Create/Delete a new ip interface/route/arp entry on the GigE port

portcfgalpa Set AL_PA to 0x0 (default) or 0x13 portcfgautodisable Configure auto disable portcfgcreditrecovery Configure credit recovery

portcfgdefault Restore the port configuration to defaults portcfgeport Enable/Disable a port from becoming E_Port

portcfgexport Sets a port to be an EX_Port and sets and displays EX_Port configuration parameters.

portbeacon Configure a port to do port beacon

portcfgfillword Configure a port to a particular fill word portcfgfportbuffers Configure F_Port buffers portcfggport Lock a port as a G_Port

portcfgislmode Configure a port to be ISL R_RDY Mode enabled/disabled

portcfglongdistance Configure a Long Distance Port

portcfglosstov Configure frontend port signal debounce portcfglport Lock a port as a L_Port

portcfgnpivport Enables and disables NPIV functionality on a port. portcfgnport Enable/disable N_Port capability for a port portcfgpersistentdisable Persistently disable a port

portcfgpersistentenable Enable a persistently disabled port

portcfgqos Configure QoS feature

portcfgshow Displays port configuration settings.

portcfgspeed Configure a port to a particular speed level portcfgtrunkport Configure a port for trunking

portcfgvexport Sets a port to be an VEX_Port connected to FC-IP and sets and displays VEX_Port configuration parameters.

portcmd Execute commands (ping etc) on the GigE port

portdebug Set debug level and verbosity level of port modules portdisable Disable a specified port portenable Enable a specified port porterrshow Print port error summary

portflagsshow Display the port status bitmaps of all ports in a switch

portledtest Cycle user port LEDs. portlogclear Clear port activity log

portlogconfigshow Display portlog configuration portlogdisable Disable portlog facility

portlogdump Print port log (no page breaks) portlogdumpport Print port log (no page breaks) portlogenable Enables port log facility

portlogeventshow Display information about port log events portloginshow Display port login information portlogpdisc Set or clear the debug_pdisc_flag portlogreset Enable portlog facility portlogresize Resize the port log portlogshow Print port activity log portlogshowport Print port activity log portlogtypedisable Disable port logging portlogtypeenable Enable port logging

portloopbacktest Functional test of port N->N path.

portmirror Set a port's configuration to be disabled or enabled

portname Assign or display the name associated with a port portperfshow Print port throughput numbers

portregtest Write/read test of the ASIC SRAMs portregtest. portrouteshow Display various routing tables for a port

portshow Show configured ip interfaces/routes/arp entries on the GigE Port

portstats64show Display the 64-bit hardware statistics for a port portstatsclear Clear the status of a specified switch port portstatsshow Print hardware statistics portswap Swaps area numbers

portswapdisable Disable portswap feature

portswapenable Enable portswap feature

portswapshow Display port and area information

porttest Functional test on a live fabric. Starts porttest. porttestshow Retreive information from porttest. porttrunkarea Configure area trunking

portzoneshow Displays the enforced zone type of the F/FL-ports of a switch.

powerofflistset sets slot power off list order powerofflistshow Displays slot power-off order. psshow Print power supply status

quietmode Displays/enables/disables quietmode on telnet session

reboot Reboot this processor routehelp Print routing help info

saschiptest Functional Test of Components in SAS Complex. saspathtest Data Path Test of the SAS complex.

secactivesize Displays size of the active (security) database secauthsecret Creates/Manages DHCHAP secret key details seccertutil Creates/Manages/Displays third party PKI certificates

secdefinesize Displays size of the defined (security) database secglobalshow Displays current internal security state information

sechelp Displays information about security commands secpolicyabort Aborts changes to defined policy secpolicyactivate Activates all policy sets

secpolicyadd Adds members to an existing policy secpolicycreate Creates a new policy

secpolicydelete Deletes an existing policy

secpolicydump Displays all members of existing policies secpolicyfcsmove Moves a member in the FCS policy

secpolicyremove Removes members from an existing policy

secpolicysave Saves defined policy set and sends to all switches secpolicyshow Shows members of one or more policies secstatsreset Resets security statistics secstatsshow Displays security statistics sensorshow Display sensor readings

setdbg Set debug level of the specified module setesdmode Set or display ESD mode.

setmfgmode Set or display diagnostic MFG mode.

setmodem Enables or disables modem login to a control processor (CP)

setsplbmode Set or display SPLB mode.

setverbose Set verbosity level of the specified module

sfpshow Print Serial ID SFP information

shellflowcontroldisable Disable xon-xoff flow control on console serial port

shellflowcontrolenable Enable xon-xoff flow control on console serial port slotpoweroff Removes power from a slot. slotpoweron Restores power to a slot.

slotshow Displays the status of all slots in the system. sltest Serial link test of port N->N path. snmpconfig Configure SNMP

snmpmibcapset Set options for configuring SNMP Mib/Trap Capability

snmpmibcapshow Show SNMP Mib/Trap Configuration

spinfab Functional test of switch to switch ISL cabling and trunk group operation.

spinjitter line-speed jitter measurement

spinsilk Functional test of internal and external transmit and receive paths at full speed

sramretentiontest Data retention test of the miscellaneous SRAMs in ASIC.

sshutil Configure SSH authentication options statsclear Clear port and diagnostic statistics. statstest Statistics counter test for the ASICs. stopporttest Terminate the running porttest.

supportffdc Modifies or displays first-failure data capture (FFDC) configuration.

supportftp set support Ftp parameters

supportsave retrieve support data from switch to host

supportshow Prints switch information for debugging purposes. supportshowcfgdisable Disables a group of commands under supportshow command.

supportshowcfgenable Enables a group of commands under supportshow command.

supportshowcfgshow Displays the groups of commands enabled for display. by the supportshow command.

switchbeacon Set switch beacon on or off switchcfgpersistentdisable Persistently disable a switch

switchcfgpersistentenable Enable a persistently disabled switch

switchcfgspeed Configures all ports of the switch to a particular speed level

switchcfgtrunk Configure all ports on the switch for trunking switchdisable Disable this switch switchenable Enable this switch

switchname Print/set this switch's name switchshow Print switch and port status

switchstatuspolicyset Set policy parameters for overall switch status switchstatuspolicyshow Print policy parameters for overall switch status switchstatusshow Print overall switch status

switchuptime Display the amount of time for which the switch is up

switchviolation Display policy violations recorded in RAS log syslogdfacility Change the syslog facility syslogdipadd Add syslog daemon IP address syslogdipremove Remove syslog daemon IP address syslogdipshow Print the syslog daemon targets

sysshutdown Provides a graceful shutdown to protect the switch file systems.

systemverification Run a suit of diagnostic tests on all switches in a system.

tempshow Print temperature readings

timeout Set/show the IDLE timeout value for a login session topologyshow Display the unicast fabric topology

tracedump generate/remove trace dump or display trace dump status

traceftp enable/disable trace auto-FTP or transfer trace dump

trackchangeshelp Print Track Changes help info

trackchangesset Configure alert for login/logout/config update trackchangesshow Displays status of track changes trunkdebug Debug a trunk link failure trunkshow Display trunking information

tsclockserver Displays or sets the NTP server address tstimezone Displays or sets the time zone turboramtest Turbo SRAM test for bloom ASICs.

txdpath Functional test of ASIC pair TXA TXD connections. uptime Print how long switch has been up urouteconfig Configure a static route urouteremove Remove a static route

urouteshow Display unicast routing information

usbstorage Manage USB storage device (available on Brocade Data Center Director only).

userconfig Display or configure user accounts userrename Rename user login name version Print firmware version

wwn Display or set the world wide name zone Configure zone objects zoneadd Add a member to a zone zonecreate Create a zone zonedelete Delete a zone

zonehelp Print zoning help info zoneobjectcopy Copies a zone object zoneobjectexpunge Expunges a zone object zoneobjectrename Rename a zoning Object

zoneremove Remove a member from a zone zoneshow Print zone information